What a 13 kW solar system costs in Darwin
$18,970 to $23,189 is the Darwin range for a 13 kW system in October 2026, derived by scaling the Solar Choice Darwin 10 kW offer with the commercial index ratio because no residential index exists at 13 kW; after STCs and GST that is 1.46 to 1.78 dollars per watt. They are offers submitted by installers to the Solar Choice platform, not quotes received by Darwin homeowners. No checked Darwin quotes are counted yet; once the quote check holds ten or more for Darwin this page will add a quotes series with the median, the quartiles and the count.
| System | Standard offer | Premium offer | STC discount (Zone 2) | $ per watt |
|---|---|---|---|---|
| 5 kW | $8,470 | $9,950 | 38 STCs, $1,482 | 1.69 to 1.99 |
| 6.6 kW | $10,250 | $12,260 | 50 STCs, $1,950 | 1.55 to 1.86 |
| 8 kW | $11,970 | $14,537 | 61 STCs, $2,379 | 1.50 to 1.82 |
| 10 kW | $14,930 | $18,250 | 76 STCs, $2,964 | 1.49 to 1.82 |
| 13 kW | $18,970 | $23,189 | 99 STCs, $3,861 | 1.46 to 1.78 |
| 20 kW | $28,398 | $34,713 | 153 STCs, $5,967 | 1.42 to 1.74 |
Treat the Darwin 13 kW figure as a derived benchmark rather than an index reading, and expect quotes to spread around it. In Darwin the jump from 10 kW to 13 kW adds $4,040 on the standard offer for 7 more panels at 440 W, 30 panels in all.
Battery-ready sizing: why 13 kW in Darwin
A battery is charged from what the house does not use in daylight, so battery-ready sizing in Darwin starts from the surplus. A 13 kW array makes about 20,878 kWh a year in Darwin, 57.2 kWh on an average day, and at 35 per cent daytime use leaves 37.2 kWh a day to charge a battery.
In February, the weakest Darwin month, output falls to 1,465 kWh, or 52.3 kWh a day, which leaves about 34.0 kWh a day of surplus; that is the month the battery size should be checked against, not the summer peak of 2,019 kWh in October.
A hybrid inverter in the 5 kW to 10 kW class lists at $3,449 to $5,399 ex GST on the Greentech price list, and a 13 kW array in Darwin usually pairs with a 10 kW hybrid at the top of that range.
| Month | Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| kWh | 1,564 | 1,465 | 1,745 | 1,753 | 1,712 | 1,586 | 1,704 | 1,877 | 1,915 | 2,019 | 1,842 | 1,696 |
The 14 kWh battery tier in Darwin
For a Darwin home the federal Cheaper Home Batteries Program pays 6.8 STCs per usable kWh on the first 14 kWh, then 60 per cent of that to 28 kWh and 15 per cent to 50 kWh. At $39 per STC a 10 kWh battery in Darwin attracts $2,652, 14 kWh attracts $3,705 and 20 kWh attracts $4,641, because only 17.6 of the 20 kWh count.
| Usable capacity | Eligible kWh | Certificates | Discount |
|---|---|---|---|
| 10 kWh | 10 kWh | 68 | $2,652 |
| 14 kWh | 14 kWh | 95 | $3,705 |
| 20 kWh | 17.6 kWh | 119 | $4,641 |
The discount per kWh is $265 up to 14 kWh and falls after it, which is why 14 kWh is the tier most Darwin battery-ready quotes aim at. The factor steps down to 5.7 STCs per kWh on 1 January 2027 for Darwin installs.
Matching a 13 kW array to a 10 to 14 kWh battery in Darwin
With 37.2 kWh a day of average surplus in Darwin, a 13 kW array fills a 10 kWh battery on most days and a 14 kWh battery on average days from spring to autumn, while in February the 34.0 kWh surplus fills about 243 per cent of 14 kWh. A 10 kW array in Darwin makes 16,060 kWh a year, 4,818 kWh less, which is the difference between filling the battery and topping it up from the grid in winter.
Evening use in Darwin is worth 29 cents a kWh against 9.13 cents for export, so each kWh the battery shifts is worth about 19.87 cents more than exporting it. The payback of the 13 kW array alone in Darwin is 5.6 to 6.9 years on a saving of $3,358 a year; the battery's payback is a separate calculation on the battery guide.
Three phase for 13 kW in Darwin
A 13 kW array needs an inverter of at least 9.77 kW under the 133 per cent rule, so in practice it is a three-phase system in Darwin. Power and Water publishes a 10 kVA single-phase inverter limit for Darwin, so a 13 kW array can sit on single phase with export limiting where the installer gets approval. The three-phase export cap is 7 kW.
The three-phase inverter adds $375 to $1,500 on the sourced range, and over 25 years the Darwin array makes about 491,801 kWh, which puts the standard offer at 3.9 cents per kWh and the premium offer at 4.7 cents against 29 cents from the the Northern Territory grid.
| System | 25-year generation | Standard offer | Premium offer |
|---|---|---|---|
| 5 kW | 189,154 kWh | 4.5 c | 5.3 c |
| 6.6 kW | 249,684 kWh | 4.1 c | 4.9 c |
| 8 kW | 302,647 kWh | 4.0 c | 4.8 c |
| 10 kW | 378,309 kWh | 3.9 c | 4.8 c |
| 13 kW | 491,801 kWh | 3.9 c | 4.7 c |
| 20 kW | 756,617 kWh | 3.8 c | 4.6 c |
STC audit for 13 kW in Darwin (Zone 2)
13 kW of panels in Darwin earns 99 certificates: 13 x 1.536 (Zone 2) x 5 years = 99.84, rounded down, which is $3,861 at $39 per STC. A battery on the same Darwin quote earns its own certificates under the battery program and should be a separate line.
Test the Darwin quote by comparing its panel STC line with $3,861; if it is 10 per cent or more lower, the installer has priced the certificates below the market and the money is coming back through the hardware. In 2027 the same 13 kW system in Darwin earns 79 certificates worth $3,081.
| System | kW x zone factor x years | Certificates (rounded down) | Value in 2026 | From 1 January 2027 |
|---|---|---|---|---|
| 5 kW | 5.0 x 1.536 x 5 = 38.40 | 38 | $1,482 | 30 STCs, $1,170 |
| 6.6 kW | 6.6 x 1.536 x 5 = 50.69 | 50 | $1,950 | 40 STCs, $1,560 |
| 8 kW | 8.0 x 1.536 x 5 = 61.44 | 61 | $2,379 | 49 STCs, $1,911 |
| 10 kW | 10.0 x 1.536 x 5 = 76.80 | 76 | $2,964 | 61 STCs, $2,379 |
| 13 kW | 13.0 x 1.536 x 5 = 99.84 | 99 | $3,861 | 79 STCs, $3,081 |
| 20 kW | 20.0 x 1.536 x 5 = 153.60 | 153 | $5,967 | 122 STCs, $4,758 |
Network rules in Darwin: Power and Water
Homes in Darwin connect to the Power and Water network, and Power and Water sets the limits that decide which system size is worth paying for.
| Rule | Value |
|---|---|
| Largest inverter on single phase | 10 kVA |
| Export limit on single phase | 5 kW |
| Largest inverter on three phase | 30 kVA |
| Export limit on three phase | 7 kW |
Power and Water did not allow its connection standard to be read automatically on 27 October 2026; the limits above are as reported in published installer guides of 2026 and will be replaced with the standard's own wording at the next review. Ask the installer to write the export limit they applied for on the quote.
On a single-phase connection the export cap is 5 kW, so the extra $4,680 that a 10 kW system costs over 6.6 kW in Darwin buys panels whose midday output you cannot sell. In Darwin it only pays if you use that power at home: a battery, an EV charger, a pool pump or daytime hot water. Ask the Darwin installer which limit applies to your meter before you choose the size.
State support for a 13 kW system in the Northern Territory
In Darwin, as across the Northern Territory: The Northern Territory's Home and Business Battery Scheme, which paid $400 per kWh up to $12,000, closed to new grants in June 2025 and has not reopened; Territory installs rely on the federal STC discount, worth more here than anywhere else because the NT is STC Zone 1, and the federal battery discount; Checked at nt.gov.au on 27 October 2026. The STC discount of $3,861 on 13 kW in Darwin is federal and applies on top. Detail on the NT solar rebates page.
Other system sizes in Darwin
The 13 kW national page compares the eight capitals, and the Darwin solar prices page carries every size, the price index and the suburb pages for Darwin. The other five sizes for Darwin are below.
Get 13 kW quotes in Darwin
Request quotes through Solar Scorecard and we text you first, then pass the enquiry to up to two vetted installers who service Darwin. If a Darwin 13 kW quote is already on the table, run it through the quote check and it is measured against the $18,970 to $23,189 range and the $3,861 STC line on this page.
13 kW in Darwin: questions
How much does a 13kW solar system cost in Darwin?
$18,970 to $23,189 in Darwin after STCs in October 2026, derived from the Solar Choice Darwin 10 kW offer scaled with the commercial index, or 1.46 to 1.78 dollars per watt.
How much does a 13.2kW solar system cost in Darwin?
$18,970 to $23,189 in Darwin after STCs in October 2026: this page prices 13 kW as 30 panels at 440 W, which is 13.2 kW, so a 13.2 kW quote in Darwin compares directly with this range.
What size battery suits a 13kW system in Darwin?
10 kWh to 14 kWh: the Darwin array leaves about 37.2 kWh a day of surplus at 35 per cent daytime use, and 14 kWh is the last kWh that earns the full 6.8 STCs per kWh under the federal discount.
How much is the battery rebate on 14kWh in Darwin?
$3,705 at $39 per STC for a 14 kWh battery installed in Darwin before 31 December 2026; 10 kWh attracts $2,652 and 20 kWh attracts $4,641.
Does 13kW need three phase in Darwin?
9.77 kW is the smallest inverter the 133 per cent rule allows under 13 kW of panels, which is well past the 5 kVA single-phase norm, so a 13 kW system in Darwin is a three-phase job unless the installer secures approval for a limited single-phase connection.
How much does 13kW generate in Darwin?
20,878 kWh a year, 57.2 kWh a day on average, from 1,606 kWh per kW at Darwin Airport; over 25 years about 491,801 kWh at 3.9 cents per kWh on the standard offer.
How many STCs does a 13kW system get in Darwin?
99 certificates for Darwin in Zone 2, worth $3,861 at $39 each in 2026 and 79 certificates worth $3,081 from 1 January 2027.